● ONLINE

Affichage de 1–12 sur 21 résultats

  • Plus3L-600G

    Voltage: 220/230/240Vac
    Voltage Range : -30%, +25%
    Frequency : 50/60Hz(auto-sensing)
    Cable Plug Type : German plug power cable Voltage (DC mode) : 220/230/240Vac +/-10% Frequency : 50/60Hz +/-1Hz
    Waveform : Simulated Sinewave
    Steps of Regulation : II Boost + I Buck Transfer Time : <6ms typical Recharge Time(to 90%):5hrs

    Vue Rapide
  • Plus3L-800G

    Voltage: 220/230/240Vac
    Voltage Range : -30%, +25%
    Frequency : 50/60Hz(auto-sensing)
    Cable Plug Type : German plug power cable Voltage (DC mode) : 220/230/240Vac +/-10% Frequency : 50/60Hz +/-1Hz
    Waveform : Simulated Sinewave
    Steps of Regulation : II Boost + I Buck Transfer Time : <6ms typical Recharge Time(to 90%):5hrs

    Vue Rapide
  • PlusI-10KLB

    Phase:1P2W+G, 220/230/240VAC
    Voltage Range:110VAC-276VAC
    Frequency:50Hz or 60Hz (auto-sensing )
    THDi : <5% with R ful load
    Terminal Block : Yes
    Voltage : 220/230/240VAC
    Voltage Regulation : +/-1%
    Frequency (Battery Mode) : 50Hz or 60Hz +/-0.05Hz
    THD : < 2%(Linear load) , < 5%(non-linear load) Waveform : Pure Sinewav e Crest Ratio : 3:1
    Terminal Block : Yes

    Vue Rapide
  • PlusI-10KLB

    Phase : 1P2W+G, 220/230/240VAC Voltage Range : 110VAC-276VAC Frequency : 50Hz or 60Hz (auto-sensing) THDi : <5% with R ful load Terminal Block : Yes Voltage : 220/230/240VAC Voltage Regulation : +/- 1% Waveform : Pure Sinewave Crest Ratio : 3:1

    Vue Rapide
  • PlusI-1KLB

    Phase:1P2W+G, 220/230/240VAC
    Voltage Range : 100VAC-300VAC
    Frequency: 45Hz-55Hz / 54Hz-66Hz
    THDi : <5% (Typical) at 100% linear load
    Voltage : 220/230/240VAC
    Voltage Regulation : +/-2%
    Frequency (Battery Mode): 50Hz or 60Hz +/-0.05Hz THD: < 1%(Linear load) , < 5%(non-linear load) Waveform: Pure Sinewave
    Crest Ratio : 3:1

    Vue Rapide
  • PlusI-2KLB

    Phase:1P2W+G, 220/230/240VAC
    Voltage Range : 100VAC-300VAC
    Frequency: 45Hz-55Hz / 54Hz-66Hz
    THDi : <5% (Typical) at 100% linear load
    Voltage : 220/230/240VAC
    Voltage Regulation : +/-2%
    Frequency (Battery Mode): 50Hz or 60Hz +/-0.05Hz THD: < 1%(Linear load) , < 5%(non-linear load) Waveform: Pure Sinewave
    Crest Ratio : 3:1

    Vue Rapide
  • PlusI-3KLB

    Phase:1P2W+G, 220/230/240VAC
    Voltage Range : 100VAC-300VAC
    Frequency: 45Hz-55Hz / 54Hz-66Hz
    THDi : <5% (Typical) at 100% linear load
    Voltage : 220/230/240VAC
    Voltage Regulation : +/-2%
    Frequency (Battery Mode): 50Hz or 60Hz +/-0.05Hz THD: < 1%(Linear load) , < 5%(non-linear load) Waveform: Pure Sinewave
    Crest Ratio : 3:1

    Vue Rapide
  • PlusI-6KLB

    Phase:1P2W+G, 220/230/240VAC
    Voltage Range:110VAC-276VAC
    Frequency:50Hz or 60Hz (auto-sensing )
    THDi : <5% with R ful load
    Terminal Block : Yes
    Voltage : 220/230/240VAC
    Voltage Regulation : +/-1%
    Frequency (Battery Mode) : 50Hz or 60Hz +/-0.05Hz
    THD : < 2%(Linear load) , < 5%(non-linear load) Waveform : Pure Sinewav e Crest Ratio : 3:1
    Terminal Block : Yes

    Vue Rapide
  • PlusIII-1KLRB

    Phase : 1P2W+G, 220/230/240VAC Voltage Range : 110VAC-300VAC Frequency: 50Hz or 60Hz (Auto Sensing) THDi : <5% at full load Voltage : 220/230/240VAC Voltage Regulation : +/- 2% Waveform : Pure Sinewave Crest Ratio : 3:1

    Vue Rapide
  • PlusIII-3KLRB

    Phase : 1P2W+G, 220/230/240VAC Voltage Range : 110VAC-300VAC Frequency: 50Hz or 60Hz (Auto Sensing) THDi : <5% at full load Voltage : 220/230/240VAC Voltage Regulation : +/- 2% Waveform : Pure Sinewave Crest Ratio : 3:1

    Vue Rapide
  • PlusPRO 1-1000

    “-Phase:1P2W+G, 220/230/240VAC
    -Voltage Range:100VAC-300VAC
    -Frequency:45Hz-55Hz / 54Hz-66Hz
    -THDi:<5% (Typical) at 100% linear load
    -Plug Type of Cable:German plug power cable
    -Voltage:220/230/240VAC
    -Frequency (Battery Mode):50Hz or 60Hz +/-0.05Hz
    -THD:< 1%(Linear load) , < 5%(non-linear load)
    -Waveform:Pure Sinewave
    -Crest Ratio:3:1
    -Interface:USB port
    -E.P.O.:Emergency Power Off
    -Recharging Time:5hrs to 90%”

    Vue Rapide
  • PlusPRO 1-10KT

    -Phase:1P2W+G, 220/230/240VAC

    -Voltage Range:110VAC-276VAC -Frequency:50Hz or 60Hz (auto-sensing)

    -THDi:<5% with R ful load

    -Terminal Block:Yes
    -Voltage:220/230/240VAC -Voltage Regulation:+/- 1%

    -Frequency (Battery Mode):50Hz or 60Hz +/-0.05Hz -THD:< 2%(Linear load) , < 5%(non-linear load)

    -Waveform:Pure Sinewave -Crest Ratio :3:1 -Terminal Block :Yes – To AC Mode:> 92% at full load and battery fully charged

    -To Battery Mode:> 92% at full load and 12VDC battery

    -ECO Mode:> 96% at full load and battery fully charged

    -Interface:USB port

    -Intelligent Slot:Slot for SNMP or SNMP card (Optional) -E.P.O :Emergency Power Off

    Vue Rapide
X