Description
FEATURES
• Providing simultaneous measurement at EPON/GPON/GEPON for all three wavelengths on the fiber (1490nm, 1550nm,1310nm )
• Used in burst mode measurement of 1310nm upstream
• Convenience for threshold setting, which can set the threshold on the tester
• USB communication port enables data transfer to a PC
• Offers up to 10 different threshold sets in total
• User self-calibration can be retrieved in computer through the software
• 10 minutes Auto-off function can be activated or deactivated with keypad operation
SPECIFICATIONS
Wavelength | 1310nm | 1490nm | 1550nm |
Pass Zone(nm) | 1260 ~1360 | 1470~1505 | 1535~1570 |
Isolation (dB) | >40@1490 | >30@1310 | >40@1310 |
Isolation(dB) | >40@1550 | >40@1550 | >40@1490 |
Measurement Range(dBm) | -40~+10 | -40~+10 | -40~+20 |
Measurement Accuracy | |||
Uncertainty(dB) | ±0.5 | ||
Linearity(dB) | ±0.1 | ||
Passing through insertion Loss(dB) | <1.5 | ||
General Information | |||
Detector Type | InGaAs | ||
Optical Connector | SC/PC (TC-80A) SC/APC (TC-80B) | ||
Fiber Type | 9/125um | ||
Display | LCD:128*64 | ||
Measurement Unit | dB/dBm/xW | ||
Resolution (dB) | 0.01 | ||
Power Supply | 3* AA1.5V battery | ||
Operation Temperature(℃) | -10~60 | ||
Storage temperature(℃) | -25~70 | ||
Dimension(mm) | 200 X90 X50 | ||
Weight(g) | 285 |